Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/5856
Título: Simultaneous and enantioselective liquid chromatographic determination of eslicarbazepine acetate, S-licarbazepine, R-licarbazepine and oxcarbazepine in mouse tissue samples using ultraviolet detection
Autor: Alves, Gilberto 
Figueiredo, Isabel 
Castel-Branco, Margarida 
Loureiro, Ana 
Falcão, Amílcar 
Caramona, Margarida 
Palavras-chave: Eslicarbazepine acetate; Oxcarbazepine; Mouse tissue samples; Enantioselective liquid chromatography; Bioanalytical method validation
Data: 2007
Citação: Analytica Chimica Acta. 596:1 (2007) 132-140
Projeto: SFRH/12694/2003 
Título da revista, periódico, livro ou evento: Analytica Chimica Acta
Volume: 596
Número: 1
Resumo: Herein is reported, for the first time, a simple and reliable chiral reversed-phase liquid chromatographic method coupled to ultraviolet (UV) detection for simultaneous determination of eslicarbazepine acetate (ESL) and its metabolites, S-licarbazepine (S-LC), R-licarbazepine (R-LC) and oxcarbazepine (OXC), in mouse plasma and brain, liver and kidney tissue homogenates. All analytes and the internal standard were extracted from plasma and tissue homogenates by a solid-phase extraction procedure using Waters Oasis® hydrophilic-lipophilic balance cartridges. The chromatographic separation was performed by isocratic elution with water/methanol (88:12, v/v), pumped at a flow rate of 0.7 mL min-1, on a LichroCART 250-4 ChiraDex ([beta]-cyclodextrin, 5 [mu]m) column at 30 °C. The UV detector was set at 225 nm. Calibration curves were linear (r2 >= 0.996) in the ranges 0.4-8 [mu]g mL-1, 0.1-1.5 [mu]g mL-1 and 0.1-2 [mu]g mL-1 for ESL and OXC and in the ranges 0.4-80 [mu]g mL-1, 0.1-15 [mu]g mL-1 and 0.1-20 [mu]g mL-1 for R-LC and S-LC in plasma, brain and liver/kidney homogenates, respectively. The overall precision not exceeded 11.6% (%CV) and the accuracy ranged from -3.79 to 3.84% (%bias), considering all analytes in all matrices. Hence, this method will be a useful tool to characterize the pharmacokinetic disposition of ESL in mice.
URI: https://hdl.handle.net/10316/5856
DOI: 10.1016/j.aca.2007.05.056
Direitos: openAccess
Aparece nas coleções:FFUC- Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
file12a5a325bdca470cb38c1cce02baf899.pdf472.87 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

27
Visto em 15/abr/2024

Citações WEB OF SCIENCETM

24
Visto em 2/abr/2024

Visualizações de página 50

591
Visto em 16/abr/2024

Downloads 50

377
Visto em 16/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.