dc.description.abstractThe gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedback due to the additional scintillation produced in the electron avalanche process at the MSP anodes, in the absence of quenching. A low-photoelectron collection efficiency is achieved in the gas atmosphere, resulting in a scintillation conversion efficiency that is about a factor of 5 lower than that achieved with PMT-based GPSCs. However, energy resolutions of 11% for 5.9 keV X-rays are achieved with this detector.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-486BN6Y-M/1/4da741da1d82059bc939bc52156b6569en_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectGas scintillation counteren_US
dc.subjectCsI photocathodeen_US
dc.titleThe gas proportional scintillation counter/microstrip gas chamber hybrid detectoren_US
dc.typearticleen_US
dc.identifier.doi10.1016/S0168-9002(03)01058-1-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-7107-7203-
crisitem.author.orcid0000-0002-1912-2804-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
file9f1530d1081c4248b0b8b3c1ef76d362.pdf228.34 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

7
checked on Apr 15, 2024

WEB OF SCIENCETM
Citations

7
checked on Apr 2, 2024

Page view(s)

328
checked on Apr 23, 2024

Download(s)

286
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.