Título: | Measurement of the refractive index and attenuation length of liquid xenon for its scintillation light | Autor: | Solovov, V. N. Chepel, V. Lopes, M. I. Hitachi, A. Marques, R. Ferreira Policarpo, A. J. P. L. |
Palavras-chave: | Liquid xenon; Refractive index; Vacuum ultraviolet; Scintillation | Data: | 2004 | Citação: | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 516:2-3 (2004) 462-474 | Resumo: | The attenuation length and refractive index of liquid xenon for its intrinsic scintillation light ([lambda]=178 nm) have been measured in a single experiment. The value obtained for the attenuation length is 364±18 mm. The refractive index is found to be 1.69±0.02. Both values were measured at a temperature of 170±1 K. | URI: | https://hdl.handle.net/10316/4453 | DOI: | 10.1016/j.nima.2003.08.117 | Direitos: | openAccess |
Aparece nas coleções: | FCTUC Física - Artigos em Revistas Internacionais |