Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4378
DC FieldValueLanguage
dc.contributor.authorMir, J. A.-
dc.contributor.authorStephenson, R.-
dc.contributor.authorRhodes, N. J.-
dc.contributor.authorSchooneveld, E. M.-
dc.contributor.authorVeloso, J. F. C. A.-
dc.contributor.authorSantos, J. M. F. dos-
dc.date.accessioned2008-09-01T11:06:06Z-
dc.date.available2008-09-01T11:06:06Z-
dc.date.issued2007en_US
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 573:1-2 (2007) 179-182en_US
dc.identifier.urihttps://hdl.handle.net/10316/4378-
dc.description.abstractExperimental work was carried out to evaluate the performance of a Gas Electron Multiplier (GEM) operated with a micromesh readout plane that enabled the induction gap to be set at 50 [mu]m. We measured the essential operational parameters of this system using Ar(75%)-isobutane (25%) as the counter gas mixture. The measurements included the effective gain, effective gain stability, and the X-ray energy resolution using a 5.89 keV X-ray source. These studies demonstrated several advantages of the current system when compared with the standard operation, such as lower operational voltages, higher effective gains and improved effective gain stability.en_US
dc.description.urihttp://www.sciencedirect.com/science/article/B6TJM-4MCW7M1-F/1/f0700659b4d61e87ecd815040c63b24aen_US
dc.format.mimetypeaplication/PDFen
dc.language.isoengeng
dc.rightsopenAccesseng
dc.subjectGas Electron Multiplieren_US
dc.subjectEffective gainen_US
dc.subjectX-ray energy resolutionen_US
dc.titleShort induction gap gas electron multiplier (GEM) for X-ray spectroscopyen_US
dc.typearticleen_US
dc.identifier.doi10.1016/j.nima.2006.10.228-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitLIBPhys - Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics-
crisitem.author.parentresearchunitUniversity of Coimbra-
crisitem.author.orcid0000-0002-7107-7203-
crisitem.author.orcid0000-0002-8841-6523-
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
filec9552558548b4a27b5aa7a7d68fc1df2.pdf155.13 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

13
checked on Nov 17, 2022

WEB OF SCIENCETM
Citations

13
checked on May 2, 2023

Page view(s)

359
checked on Apr 17, 2024

Download(s)

288
checked on Apr 17, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.