Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/4360
Title: Operation of gas electron multipliers in pure xenon at low temperatures
Authors: Solovov, V. 
Balau, F. 
Neves, F. 
Chepel, V. 
Pereira, A. 
Lopes, M.I. 
Keywords: Two-phase detectors; Gas electron muliplier
Issue Date: 2007
Citation: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 580:1 (2007) 331-334
Abstract: Operation of Gas Electron Multiplier (GEM) in ultra-pure xenon was studied for gas at 25 °C, cold but not saturated gas at -90 °C and saturated xenon vapour at -102 °C. The most stable operation was observed at -90 °C for which the maximum visible gain of 150 was obtained from a single GEM. The maximum gain of [approximate]40 was achieved for saturated xenon vapour at -102 °C and of [approximate]25 for two-phase configuration at the same temperature. Continuous operation of a GEM in two-phase mode for periods of several hours was routinely achieved.
URI: https://hdl.handle.net/10316/4360
DOI: 10.1016/j.nima.2007.05.168
Rights: openAccess
Appears in Collections:FCTUC Física - Artigos em Revistas Internacionais

Files in This Item:
File Description SizeFormat
file251d8fffabbc48b0b666ee7328e95917.pdf154.73 kBAdobe PDFView/Open
Show full item record

SCOPUSTM   
Citations

7
checked on Nov 9, 2022

WEB OF SCIENCETM
Citations

6
checked on May 2, 2023

Page view(s)

266
checked on Apr 23, 2024

Download(s)

241
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.