Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/27894
Título: Assessment of indoor air quality and thermal comfort in Portuguese secondary classrooms: methodology and results
Autor: Pereira, Luísa Dias 
Raimondo, Daniela 
Corgnati, Stefano Paolo 
Silva, Manuel Gameiro da 
Palavras-chave: Indoor air quality; Thermal comfort; Metabolic carbon dioxide; School; PMV/PPD indices
Data: Nov-2014
Editora: Elsevier
Citação: PEREIRA, Luísa Dias [et. al] - Assessment of indoor air quality and thermal comfort in Portuguese secondary classrooms: methodology and results. "Building and Environment". ISSN 0360-1323. Vol. 81 (2014) p. 69–80
Título da revista, periódico, livro ou evento: Building and Environment
Volume: 81
Resumo: This work shows the results of a field study about indoor thermal comfort, based on investigations in Portuguese secondary schools' classrooms. The surveys herein presented were carried out in a school in Beja, in the South-East of Portugal. The field study was conducted by physical parameters monitoring and survey questionnaires. Both field monitoring and subjective surveys were performed at the same time during the regular class period (either at the end or at the beginning of the class). The measurement campaign consisted in measuring the environmental parameters – air temperature (Ta), air relative humidity (RH), CO2 concentrations. Outdoor air temperature values were registered hourly at the nearest climatological station. Through these data, along with the actual people clothing and metabolic rate being know, both Fanger's comfort indices were calculated (predicted mean vote and predicted percentage of dissatisfied people). The subjective survey investigated the thermal acceptability, the thermal sensation and the thermal preference. The judgments about the thermal environment were compared with the results of the field measurements. Draught preference votes, air stiffness and global air quality votes were also collected. The results show that the students found temperature range beyond the comfort zone acceptable, and revealed the occupants' accommodation to CO2 exposure, confirming the results obtained in other studies. Moreover, it was verified that running on naturally ventilation mode, CO2 concentration limits were highly exceeded.
URI: https://hdl.handle.net/10316/27894
ISSN: 0360-1323
DOI: 10.1016/j.buildenv.2014.06.008
Direitos: openAccess
Aparece nas coleções:FCTUC Eng.Mecânica - Artigos em Revistas Internacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
Assessment of indoor air quality and thermal comfort in Portuguese.pdf2.08 MBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Citações SCOPUSTM   

145
Visto em 15/abr/2024

Citações WEB OF SCIENCETM
1

121
Visto em 2/abr/2024

Visualizações de página 20

674
Visto em 16/abr/2024

Downloads 20

1.724
Visto em 16/abr/2024

Google ScholarTM

Verificar

Altmetric

Altmetric


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.