Please use this identifier to cite or link to this item: https://hdl.handle.net/10316/277
DC FieldValueLanguage
dc.contributor.authorAlmeida, Anabela Maduro de-
dc.contributor.authorCastel-Branco, Maria Margarida-
dc.contributor.authorFalcão, Amílcar-
dc.date.accessioned2008-06-17T15:03:08Z-
dc.date.available2008-06-17T15:03:08Z-
dc.date.issued2002-07-15-
dc.identifier.citationJournal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 774: 2 (2002) 215-222-
dc.identifier.issn0021-9673pt
dc.identifier.issn1570-0232pt
dc.identifier.urihttps://hdl.handle.net/10316/277-
dc.description.abstractWhen the assumption of homoscedasticity is not met for analytical data, a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line is to use weighted least squares linear regression (WLSLR). The purpose of the present paper is to stress the relevance of weighting schemes for linear regression analysis and to show how this approach can be useful in the bioanalytical field. The steps to be taken in the study of the linear calibration approach are described. The application of weighting schemes was shown by using a high-performance liquid chromatography method for the determination of lamotrigine in biological fluids as a practical example. By using the WLSLR, the accuracy of the analytical method was improved at the lower end of the calibration curve. Bioanalytical methods data analysis was improved by using the WLSLR procedure.pt
dc.format.mimetypeaplication/PDF-
dc.language.isoengpt
dc.publisherElsevierpt
dc.relationinfo:eu-repo/grantAgreement/FCT/POCTI/PRAXIS XXI/BD/18351/98/PT/CARACTERIZAÇÃO DO PERFIL NEUROFARMACOCINÉTICO DA LAMOTRIGINA EM RATOS MEDIANTE A UTILIZAÇÃO DE MICRO- DIÁLISEpt
dc.rightsopenAccesspt
dc.subjectregressão linearpt
dc.subjectmétodos bioanalíticospt
dc.subjectcurvas de calibraçãopt
dc.titleLinear regression for calibration lines revisited: weighting schemes for bioanalytical methodspt
dc.typearticle-
degois.publication.firstPage215pt
degois.publication.lastPage222pt
degois.publication.issue2pt
degois.publication.titleJournal of Chromatography Bpt
dc.date.updated2022-07-30T21:21:17Z-
dc.peerreviewedyespt
dc.identifier.doi10.1016/S1570-0232(02)00244-1pt
degois.publication.volume774pt
dc.description.version3910-3178-31BA | MARIA MARGARIDA COUTINHO DE SEABRA CASTEL-BRANCO CAETANO-
dc.description.versioninfo:eu-repo/semantics/publishedVersion-
dc.date.embargo2002-07-15*
uc.date.periodoEmbargo0pt
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypearticle-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.fulltextCom Texto completo-
item.languageiso639-1en-
crisitem.author.researchunitICBR Coimbra Institute for Clinical and Biomedical Research-
crisitem.author.parentresearchunitFaculty of Medicine-
crisitem.author.orcid0000-0002-7394-3785-
crisitem.author.orcid0000-0002-6533-9932-
crisitem.author.orcid0000-0002-3854-6549-
Appears in Collections:FFUC- Artigos em Revistas Internacionais
Files in This Item:
File Description SizeFormat
Linear regression for calibration lines revisited.pdf138.37 kBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

471
checked on Nov 9, 2022

WEB OF SCIENCETM
Citations 50

474
checked on Apr 2, 2024

Page view(s) 20

735
checked on Apr 23, 2024

Download(s) 20

1,634
checked on Apr 23, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.