Please use this identifier to cite or link to this item:
https://hdl.handle.net/10316/13461
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Brett, Christopher M. A. | - |
dc.contributor.author | Muresan, Ioana | - |
dc.date.accessioned | 2010-07-13T11:53:20Z | - |
dc.date.available | 2010-07-13T11:53:20Z | - |
dc.date.issued | 2002 | - |
dc.identifier.citation | Key Engineering Materials. 230/232 (2002) 459-462 | en_US |
dc.identifier.issn | 1013-9826 | - |
dc.identifier.uri | https://hdl.handle.net/10316/13461 | - |
dc.description.abstract | The influence of different artificial body fluids on metallic corrosion, all containing chloride ion, was investigated by measurements of open circuit potential, polarisation curves and electrochemical impedance on high speed steel, chosen owing to its high rate of corrosion. Two types of electrolyte fluid were studied, the first similar to saliva and the second to plasmatic serum and experiments were carried out over a period of immersion of 4h. Electrolytes similar to saliva were artificial saliva with and without lactic acid, and Glandosane that contains sorbitol and Na- carboxymethylcellulose organic components. Similar to plasmatic serum were phosphate buffer saline (PBS) and Krebs-Ringer solution. It was found that the organic components in the fluids partially block the metal surface and reduce the corrosion rate. From the results obtained, an approximate order of corrosion rate was established as: Artificial saliva ~ Glandosane ~ Krebs- Ringer solution < Artificial saliva without lactic acid ~ PBS. It is demonstrated that the equivalence of these different body fluids as bathing solutions should not be assumed. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Trans Tech Publications | en_US |
dc.rights | openAccess | en_US |
dc.subject | Artificial body fluids | en_US |
dc.subject | Saliva | en_US |
dc.subject | Steel | en_US |
dc.subject | Corrosion | en_US |
dc.subject | Passivation | en_US |
dc.title | The Influence of Artificial Body Fluids on Metallic Corrosion | en_US |
dc.type | article | en_US |
degois.publication.firstPage | 459 | en_US |
degois.publication.lastPage | 462 | en_US |
degois.publication.title | Key Engineering Materials | en_US |
dc.identifier.doi | 10.4028/www.scientific.net/kem.230-232.459 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.fulltext | Com Texto completo | - |
item.languageiso639-1 | en | - |
crisitem.author.orcid | 0000-0002-1972-4434 | - |
Appears in Collections: | FCTUC Química - Artigos em Revistas Internacionais |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
The Influence of Artificial Body Fluids.pdf | 165.65 kB | Adobe PDF | View/Open |
SCOPUSTM
Citations
11
checked on Apr 1, 2024
WEB OF SCIENCETM
Citations
7
checked on Apr 2, 2024
Page view(s)
250
checked on Apr 16, 2024
Download(s)
330
checked on Apr 16, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.