Utilize este identificador para referenciar este registo: https://hdl.handle.net/10316/13419
Título: Quantitative Evaluation and Comparison of Lung Contour Extraction Methods
Autor: Silva, José Silvestre 
Silva, Augusto 
Santos, Beatriz Sousa 
Data: Out-2000
Editora: Universidade de Aveiro. Departamento de Electrónica e Telecomunicações
Citação: Revista do DETUA. 3:2 (2000) 102-107
Título da revista, periódico, livro ou evento: Revista do DETUA
Número: 2
Local de edição ou do evento: Aveiro
Resumo: Pulmonary contours in chest CT images are closed curves that may, in some cases, exhibit multiple concave and convex irregularities. In this paper we assess the quality of pulmonary contours obtained by several fully automated methods. A comparison among these contours and corresponding manually drawn reference contours was performed and several figures of merit were assigned to each one of the automated contours extraction algorithms. Likeness between a computed contour and reference contour was measured through the Pratt figure of merit, similarity index, mean error and fraction of errors greater than 5 pixels. For each of these figures we present an exploratory statistical analysis and discuss its sensibility to the longitudinal location of the CT slice
URI: https://hdl.handle.net/10316/13419
Direitos: openAccess
Aparece nas coleções:FCTUC Física - Artigos em Revistas Nacionais

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato
Quantitative Evaluation and Comparison of Lung Contour.pdf151.79 kBAdobe PDFVer/Abrir
Mostrar registo em formato completo

Google ScholarTM

Verificar


Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.